APPROVALS: EN 14604:2005 EN60065 RED RoHS REACH
DEVICE TYPE: Mains powered smoke alarm device with wireless interlink and battery back-up.
NORMAL OPERATION: Red LED flashes every 48 second for normal operation. Green LED shows mains power on.
BATTERY LIFE: Minimum 10 years life of back up battery.
INTERLINK FREQUENCY: 868MHz
INTERLINK RANGE: Minimum 100m in open field. Range depends on the building materials and will need to be tested in each individual case.
SOUND: Audible indicator min. 85 dB @ 3 meter in anechoic chamber.
OPERATION AC/DC: 110V AC, 230V AC
LOW BATTERY INDICATION: A short acoustic “beep” will sound and LED flash every 48 seconds when the voltage is below 2.85V. In this stage it will continue for minimum 30 days, and can drive the alarm for 4 minutes.
SOUND PATTERN: Fire alarm condition is indicated by a series of three successive tones.
USAGE: Designed for installation in private homes. The alarm can be mounted on top of a conduit box or on the ceiling with the enclosed base. This alarm can be connected with other alarms from the CAVIUS Wireless alarm family or function as a stand alone alarm. Top cover designed for easy to access vacuum cleaner nozzle.
POWER CONSUMPTION: Power consumption 161mAh in the non alarm condition.
VISIBLE INDICATORS: A red LED is used to indicate the following conditions: • fire alarm condition is indicated by a flash every 0.5 second • smoke sense speed up is indicated by a flash every 2
seconds when the smoke level is at the alarm threshold • normal operation is indicated by a flash every 48 seconds • a green LED is used to show the alarm is powered by mains supply
PRODUCT WEIGHT: Base alarm weight (excluding screws, plugs and mounting ring): 200g